Which Industries Are Temperature Reducing And Pressure Reducing Valves Used In?

Oct 29, 2022 Leave a message

In modern industry, temperature and pressure reducing valves are mainly used in the following fields:


1. The temperature reducing and pressure reducing valve is mainly used to reduce the temperature of the superheated steam from the steam turbine bypass system to an effective temperature level, so as to provide power for other equipment in the factory that needs to use saturated steam.


2. As part of a desuperheating and decompression device, it reduces the temperature and pressure of superheated steam from a boiler or thermal power plant to the required working conditions for equipment, these processes include: food, textile, tobacco, brewing, paper, chemical , pharmaceutical, petrochemical, etc.


Desuperheating and pressure reducing valves are widely used in various industries, and there are many companies that make this product, but the price is really very confusing, because some have high unit prices, and some companies offer very cheap prices. This makes it difficult for customers to choose, if you choose a higher price, you are worried that it is not worth the price, if you choose a lower one, you are worried about the quality. Here, I believe that many customers understand the point of view that you get what you get for every penny, so when we choose high-quality desuperheating and pressure reducing valves, we must also choose moderately priced desuperheating and pressure reducing valves.


As the name suggests, the desuperheater and pressure reducer is to reduce high temperature and high pressure steam into low pressure and low temperature steam that can be used by customers. Taking the outlet of the boiler superheater as an example, the steam generated by the boiler reaches the steam turbine through the heater outlet for work, and the steam turbine is responsible for the input steam. Parameters have range requirements. If the steam parameters at the outlet of the superheater exceed the upper limit required by the steam turbine, the steam turbine will be damaged, therefore, temperature and pressure reduction devices must be used to reduce the parameters to the applicable range.


The desuperheater and decompressor is a desuperheater and decompression device widely used in electric power, petrochemical, light industry, textile printing and dyeing, medicine, cogeneration and other industries. When installing, please pay special attention to the following matters:


1. Please install in the order of serial numbers in the general drawing of the main system of the desuperheater and pressure reducer.


2. A gate valve should be installed at the inlet of the equipment to open and close.


3. The lower part of the safety valve of the desuperheater and pressure reducer should be provided with a fixed bracket, and a sliding bracket should be set at the appropriate position at both ends of the equipment. Thermal compensation measures or natural compensation should be considered at the connection between the two ends of the equipment. The trap must be installed? ?Installed at a low point, the user should solve the above gate valve, bracket, compensation measures, steam trap and other problems according to the above conditions.


4. Use a shielded wire with a single-core wire of 1mm2 or larger for the signal wire connecting the field instrument to the temperature control cabinet: three-core shielded wire for thermal resistance, two-core shielded wire for pressure transmitter, four-core shielded wire Shielded wire For the actuator, the grounding resistance should be less than 4 ohms, the main input wire of the power supply should be a cable of 2.5mm2 or more, and all instruments with grounding requirements must be grounded reliably.


5. Install the inlet and outlet thermal resistance and pressure transmitter in strict accordance with the installation drawings and technical data to avoid reverse installation. If the damage is caused by installation errors, it will cause subsequent use errors.


6. When installing each valve, please pay attention to the flow direction of steam and superheated water.


7. After the desuperheater and pressure reducer is installed, remove the valves of the decompression system and water supply system, and dry the entire pipeline to remove welding slag, welding nuggets and other dirt in the pipeline, and then install it again to check whether there are any Fragment, install the disassembled valve, then perform a hydraulic test, the test pressure is 1.5 times the pressure of the workpiece, the safety valve must be removed under the test pressure, sealed with a blank plate, and then pressurized for 5 minutes, check all connections for No leaks. The desuperheating and decompression device is a steam thermal energy parameter conversion device, which is widely used in modern industry, cogeneration, central heating and thermal energy projects in light industry, electric power, chemical industry and other industries. The device reduces the steam parameters provided by the user to the appropriate temperature and pressure required by the user to meet the user's requirements, and can fully save thermal energy and utilize thermal energy reasonably.


There are many structural forms of desuperheating and decompression devices, but no matter what their form is, they generally consist of desuperheating system, decompression system, main steam pipe, safety protection system, thermal control system and other systems. The specific form and structure are as follows. The structural components of the temperature reduction and pressure reduction device are composed of pressure reducing valve, steam mixing pipeline, safety valve, water supply regulating valve, throttle valve, globe valve, check valve, cooling water pipe, throttle orifice, One-piece adjustable nozzles, flanges, standard parts, etc.