Selection Analysis Of High Temperature Steam Pressure Reducing Valve

Jul 08, 2022 Leave a message

     At present, the high-pressure steam pressure reducing valves produced by domestic valve manufacturers generally have the shortcomings of low control accuracy, high noise, and can only be decompressed but not decompressed, and are not suitable for working conditions with high control accuracy requirements. At present, the high-precision, high-flow, low-noise, high-pressure pressure reducing valve industry in my country lacks high-precision, high-flow blanks. The pressure reducing valve is a valve that reduces the inlet pressure to a certain required outlet pressure through adjustment, and relies on the energy of the medium itself to keep the outlet pressure automatically stable. From the point of view of fluid mechanics, the pressure reducing valve is a throttling element whose local resistance can be changed, that is, by changing the throttling area, the flow rate and the kinetic energy of the fluid are changed, resulting in different pressure losses, so as to achieve the purpose of pressure reduction. Then rely on the adjustment of the control and adjustment system to balance the fluctuation of the pressure behind the valve with the spring force, so that the pressure behind the valve remains constant within a certain error range.

    

The pressure reducing valve is the dominant piston structure and adopts the porous pressure reducing design, which can greatly increase the gas flow, effectively eliminate the production conditions of ice blockage, prevent the influence of cavitation and cavitation on the throttle channel, and prolong the service life of the product.


Nominal diameter: DN8~DN50, the high input gas pressure can reach 40MPa, and the small output pressure can reach zero pressure. Not only can reduce dynamic pressure, but also reduce static pressure.


The compression spring adopts a combination of multiple butterfly springs, which improves the output control accuracy of the pressure reducing valve and avoids the shortcomings of traditional spring fatigue and poor accuracy. The outlet pressure can be adjusted freely as required. The control precision is high, and the pressure fluctuation range after the valve is less than or equal to 1%.


Replacing different materials and sealing materials can be applied to the pressure regulation of different gases.


The installation of the transmission can transmit the real-time valve position signal to the central control room, so as to understand the valve dynamics at will.